Roof sheathing comes in grid marked 4 by 8 foot sheets and should be installed perpendicular to the frame.
Roof sheathing nail spacing.
The typical thickness range for sheathing is 3 8 to 3 4 inch.
For clarity sheathing nails are not shown ladder framing at gable ends.
Check the nailing surface is level step 2.
Roof truss spacing will vary on the structure s construction.
Never attach roof sheathing with staples.
Spacer type panel edge clips may also be used for roof sheathing applications.
Cover sheathing with.
Boards for the floor caulking gun for 30 ounce tubes of adhesive afg 01 rated adhesive in 30 ounce tubes cleaning supplies such as rags and paint thinner fan and or light utility knife and long screwdriver to open tubes safety items including glasses or goggles and a bicycle helmet or hardhat.
To assure best performance follow these panel spacing and nailing recommendations for apa rated sheathing apa rated sturd i floor and apa rated siding.
Proper installation of apa rated sheathing for roof applications step 1.
8d ring shank nails should be used instead.
Staples have been found by both engineering testing and hurricane experience to not hold.
Ommended that deformed shank nails be used throughout the entire roof.
The type of nails you ll need to use during the sheathing process depends on the roof material thickness.
Click to expand contents.
How many nails per board in roof sheathing.
Fasten panels with a minimum of.
There are typically 12 16 or.
Provide roof ventilation according to building codes see hints below and figure 2.
For wood panel sheathing plywood or oriented strand board osb nail sizes and nail spacing commonly used particularly along trusses and rafters in the middle of the panels have been inadequate to provide the needed resistance to uplift in hurricanes.
As such the nailing schedule is typically the familiar 6 inches on center at supported panel edges including gable end walls and 12 inches on center over intermediate panel sup ports.
Screws can be used for typical layout of roof sheathing panels on gable end roof typical layout of roof sheathing panels on hip roof.
Holes drilled in roof sheathing for ventilation roof diaphragm action is maintained.
Ventilate the roof according to current building codes step 3.
Method for maintaining a continuous load path at the roof ridge by nailing roof sheathing.
Always check for level nailing surface.
Nail spacing is recommended 4 inches on center maximum.
Properly fasten panels including fastening and spacing hints step 4.
If 8d common nails are specified the nail diameter must be at least 0 131 inch wider than typical 8d pneumatic nails.
And scroll down to see more details on each with installation hints and tips below.
Use a 10d box nail to gauge 1 8 inch spacing between panels.